{"product_id":"ebac-cd30-se-low-temperature-dehumidifier-115v-60hz-r290","title":"Ebac CD30-SE Low Temperature Industrial Dehumidifier with Alarm - 24 Pints\/Day, 115V, Wall Bracket Included","description":"\u003ch2\u003eEbac CD30-SE Low Temperature Industrial Dehumidifier with Alarm - 24 Pints\/Day, 115V, Wall Bracket Included\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 110 \/ 1 \/ 60\u003cbr\u003e\u003cstrong\u003eTypical Extraction:\u003c\/strong\u003e 24 ppd\u003c\/p\u003e\u003ch3\u003eCD30-S\u003c\/h3\u003e\u003cp\u003e• Adjustable Control Humidistat\u003cbr\u003e• Convenient Drain Point Defrost\u003cbr\u003e• EIP’s Unique Hot Gas Temperature Sensitive\u003cbr\u003e• Sturdy Carrying Handles\u003cbr\u003e• Totally Enclosed Coils\u003cbr\u003e• Heavy Gauge Steel Case\u003c\/p\u003e\u003ch3\u003eCD30-SE\u003c\/h3\u003e\u003cp\u003e• Status Indicators\u003cbr\u003e• Adjustable Alarm Humidistat\u003cbr\u003e• Voltage Free Alarm Signal\u003cbr\u003e• Power On Indicator\u003cbr\u003e• Hours Run Meter\u003cbr\u003e• Wall Mounting Bracket\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eCD30-S\u003c\/th\u003e\n\u003cth\u003eCD30-SE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e11420GY-US\u003c\/td\u003e\n\u003ctd\u003e11420GS-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth (in)\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (lbs)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (A)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower (W)\u003c\/td\u003e\n\u003ctd\u003e480\u003c\/td\u003e\n\u003ctd\u003e480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow (cfm)\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level (dbA)\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffective Volume (cu.ft)\u003c\/td\u003e\n\u003ctd\u003e3,000\u003c\/td\u003e\n\u003ctd\u003e3,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtraction @ 65°F 60%RH (ppd)\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficency @ 65°F 60%RH (l\/kW)\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Extraction @ 80°F 60%RH (ppd)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Efficency @ 80°F 60%RH (l\/kW)\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Operating Temp (°F)\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Temp (°F)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eCD30-S\u003c\/th\u003e\n\u003cth\u003eCD30-SE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e11420GY-US\u003c\/td\u003e\n\u003ctd\u003e11420GS-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn\/Off Control (Via The H\/Stat)\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower On Indicator\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Defrost Control\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensative Defrost\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Gas Defrost\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcealed Humidistat\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Control Humidistat\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Alarm Humidistat\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Free Alarm Signal\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHours Run Meter\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Standing (Rubber Feet)\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eRecip\u003c\/td\u003e\n\u003ctd\u003eRecip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall Mounting Bracket\u003c\/td\u003e\n\u003ctd\u003eO\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrying Handles\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Plug Fitted\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGravity Drain (1\/2” I.D)\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEpoxy Powder Coating\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eAccessories\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e \u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1139504\u003c\/td\u003e \u003ctd\u003eWall Mounting Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3014338\u003c\/td\u003e \u003ctd\u003ePVC Tube - 12mm ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\u003ch4\u003eCD30-S\u003c\/h4\u003e\u003cp\u003e1x CD30-S Static Dryer\u003cbr\u003e1x CD30-S Owners Manual\u003cbr\u003e1x 12mm ID PVC Tube - 3m Long\u003cbr\u003e1x Jubilee Clip\u003c\/p\u003e\u003ch4\u003eCD30-SE\u003c\/h4\u003e\u003cp\u003e1x CD30-SE Static Dryer\u003cbr\u003e1x CD30-SE Owners Manual\u003cbr\u003e1x Wall mounting Bracket\u003cbr\u003e1x 12mm ID PVC Tube - 3m Long\u003cbr\u003e1x Jubilee Clip\u003cbr\u003e3x Brass Wood Screw\u003cbr\u003e3x Rawl Plug\u003c\/p\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003ch4\u003eCD30\u003c\/h4\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-S-Brochure.pdf\" target=\"_blank\"\u003eDownload CD30-S Brochure\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-S-Manual.pdf\" target=\"_blank\"\u003eDownload CD30-S Manual\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-S-Spare-Parts-List.pdf\" target=\"_blank\"\u003eDownload CD30-S Spare Parts List\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-S-Wiring-Diagram.pdf\" target=\"_blank\"\u003eDownload CD30-S Wiring Diagram\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-S-Wiring-Schematic.pdf\" target=\"_blank\"\u003eDownload CD30-S Wiring Schematic\u003c\/a\u003e\u003c\/p\u003e\u003ch4\u003eCD30E\u003c\/h4\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-SE-Brochure.pdf\" target=\"_blank\"\u003eDownload CD30-SE Brochure\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-SE-Manual.pdf\" target=\"_blank\"\u003eDownload CD30-SE Manual\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-SE-Spare-Parts-List.pdf\" target=\"_blank\"\u003eDownload CD30-SE Spare Parts List\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-SE-Wiring-Diagram.pdf\" target=\"_blank\"\u003eDownload CD30-SE Wiring Diagram\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/Ebac-CD30-SE-Wiring-Schematic.pdf\" target=\"_blank\"\u003eDownload CD30-SE Wiring Schematic\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eHow a Dehumidifier Works\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e1. Air is drawn into the unit by a fan\u003cbr\u003e2. Air passes over a cold surface\u003cbr\u003e3. As the air is cooled, it’s moisture condenses\u003cbr\u003e4. Water falls into the container\u003cbr\u003e5. Air is re-heated by the heat recovery system\u003cbr\u003e6. Air passes back into room 2°C warmer and considerably dryer\u003cbr\u003e7. Defrost system automatically de-ices unit as necessary\u003cbr\u003e8. Unit switches off automatically when container is full\u003cbr\u003e9. When the unit achieves the selected level of dryness it switches off automatically\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eThe Application\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe EIPL CD30-S and CD30-SE units are high effeciency versons of the CD30 and CD30E heavy-duty, portable dehumidifiers which are at home in hostile industrial or marine environments. Both models are ideal for both permanent installation in remote pump stations, pipe galleries, electronic and mechanical equipment areas or for quick transport between job sites and problem areas. You can rely on this durable unit to perform faithfully without complicated maintenance or costly downtime.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eProven Perfoprmance\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eUnder the operating conditions of 80°F and 60% Relative Humidity (AHAM standard, baseline used to compare the performance of industrial dehumidifiers), the CD30-S \/ CD30-SE units will remove more than 24 pints of harmful water vapor each day, additionally, nearly 4 gallons per day can be efficiently removed in an extreme environment. The CD30-S \/ CD30-SE units are definitely not “another pretty face” but tough, self sufficient performers\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eThe Problem\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eExcess humidity in your crawl space, warehouse, office factory or shop results in corrosion, mold growth and rotting. Enormous costs are incurred every year through damage to inventory and through inflated building maintenance costs as a result of dampness. Even if your building seems dry during the day, at night when the temperature falls the humidity rises and the condensation process begins. The compact physical size, and high performance, makes the CD30-S family the ideal choice for small spaces.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eThe Dehumidifier\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eEIPL dehumidifiers are effective solutions to environmental control problems. The CD ranges of units are high capacity dehumidifiers, made to operate at high efficiencies by removing moisture from the air through the refrigeration process. The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, before draining away though the condensate drain tube. Inorder for the water to flow in a gravity drainage system, the unit must be mounted higher than the drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area. Because the CD ranges of units are equipped with an internal humidistat, they automatically switch on and off to save energy and expense by maintaining the desired level of humidity with intermittent operation. The additional features of the CD30-SE make the unit the ideal choice for installations where remote monitoring is required. The alarm humidistat can be adjusted and preset during the installation process and will provide means of identifying a high humidity condition. This unit is also supplied complete with a wall mount bracket and installation kit.\u003c\/p\u003e","brand":"Ebac","offers":[{"title":"Default Title","offer_id":67806948360345,"sku":"11420GS-US","price":1300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/3681\/6793\/files\/68330d96fe90bfcea8beb998_67d823d99a3b19e97a7e9c04_TBP_2520161024-364_c80a6003-75db-465f-8af3-4960018f15fa.jpg?v=1793136963","url":"https:\/\/techforgedirect.com\/products\/ebac-cd30-se-low-temperature-dehumidifier-115v-60hz-r290","provider":"TechForge Direct","version":"1.0","type":"link"}